Battery Extra Load Units | BXL Series

Category:
Description Battery Extra Load Units | BXL Series Technical Data Mains Power Supply Connection according to IEC/EN60320-1; C320 Voltage: 90 V – 264 V AC, 50 / 60 Hz, single-phase Input power: 200 VA Dimensions and Weights Model Dimensions BXL-A 560 x 221 x 355 mm BXL-T 560 x 221 x 355 mm BXL-V 730 x 221 x 355 mm Maximum discharge current & power Model Current BXL-A 250 A BXL-T 330 A BXL-V 165 A Internal voltage measurement Model Range BXL-A 0 – 300 V DC BXL-T 0 – 75 V DC BXL-V 0 – 500 V DC Typical accuracy: ± 0,5% of reading ± 1 V Internal current measurement Model Range BXL-A 0 – 300 A DC BXL-T 0 – 450 A DC BXL-V 0 – 250 A DC Typical accuracy: ± 0,5% of reading ± 1 A Warranty 3 years additional 1 (one) year upon registration on DV Power official website (www.dv-power.com) Display LCD screen 16 characters by 2 lines LCD display with backlight, visible in bright sunlight Environment conditions Operating temperature: -20 °C to 55 °C Storage & Transportation temperature: -40 °C to 70 °C Relative humidity 0 – 95%, non-condensing Pollution degree: 2 Protection Emergency Stop button Overheat and Overvoltage protection Applicable Standards (for BLU-BXL system) EEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11, IEC 60896-22 and other relevant standards Installation/overvoltage: category II Pollution: degree 2 Safety Low Voltage Directive: Directive 2014/35/EU (CE conform) Applicable standards, for a class I instrument, pollution degree 2, Installation category II: IEC EN 61010-1 Electromagnetic Compatibility: Directive 2014/30/EU (CE conform) _Applicable standard: EN 61326-1 CAN/CSA-C22.2 No. 61010-1 Battery Extra Load Units | BXL Series