Hot

Defibrillator Life9 CU HD1 Pacemaker, NiBp/Spo2/ Temp, 5-Lead Cable

Category:
Description 1. Product overview LifeGain CU-HD1 – this is the company’s high end defibrillator/monitor intended for hospital use. It has defibrillation capabilities in AED and manual modes and may use disposable electrode pads and external and internal paddles for shock delivery. It has a transcutaneous pacer for temporary pacing of patients with low heart rate. It has an SPO2 module for the monitoring of oxygen saturation in the patient’s blood and a 12-lead ECG monitor for the evaluation and monitoring of the patient’s ECG. It has a memory card port for the storage of acquired signals and an integrated printer for the generation of hard copies of the patient’s physiological signals. These features make this defibrillator suitable for use inside a hospital.This product is a defibrillator designed for qualified emergency staff and medical professionals to deliver defibrillating shocks to victims of sudden cardiac arrest and restore the normal ECG rhythm. * AED Mode AED Mode is delivered to patients who are exhibiting the symptoms of Sudden Cardiac Arrest (SCA) including ventricular fibrillation, ventricular tachycardia, in order to bring them back to life by delivering electric shock and restoring the normal ECG rhythm. In the AED mode, defibrillation pads must be used. These defibrillation pads work to obtain the ECG signal of patients and deliver electric shock according to the patients’ condition. * Manual Mode Manual Mode is divided into two functions such as asynchronous defibrillation and synchronous cardioversion. In asynchronous defibrillation, the usage target is the same in AED Mode. For the asynchronous defibrillation treatment in the manual mode, the user is able to choose the level of electric shock energy from the range of 1-200 joule by the use of pads or paddles. On the other side, when used for synchronous cardioversion, it is used on patients with the symptoms of atrial fibrillation. It is designed to analyze the R-wave of ECG QRS and deliver R-wave synchronized electric shocks. In the Manual mode, synchronous cardioversion treatment can be delivered to patients with rapid atrial fibrillation, ventricular tachycardia, and cardiac ischemia. * Pacer Mode Pacing is a method applied to patients who had lost natural cardiac movement functions, mostly used on patients with bradycardia. LiFEGAIN CU-HD1 functions to support non-invasive pacing, a way of helping maintain a patient’s pulse by attaching its electrode to the patient’s skin and delivering artificial electric stimulation to the heart. Pacing mode is divided into the ‘Fixed mode’ and the ‘Demand mode’. * Monitoring Mode Patient monitoring mode features the ECG monitoring function and the function to measure the level of SpO2, functional oxygen saturation in the blood. For the ECG monitoring function, you can discriminatingly use the 3-lead, 5-lead, 12-lead ECG cables. During the patient monitoring session, it is possible to analyze the ECG results to use the alarming function according to the conditions such as the number of pulses, ventricular fibrillation or ventricular tachycardia etc. If using an ECG cable, convert “Rotary Switch” to “Monitor mode” before usage. * Key features Manual and AED Operation Defibrillation using paddles or pads Synchronized cardioversion Efficient and effective e-cube Biphasic technology (BTE Type) SpO2 pulse oximetry with alarm ECG monitoring (3 Lead ECG / 5 Lead ECG / 10 Lead ECG) Noninvasive pacing mode Specifications Model Name Item Description Lifegain CU-HD1 Defibrillator / Monitor Parameter Description Specified DEFIBRILLATOR Operating Modes Manual / Semi automatic Waveform Biphasic (Truncated exponential type) Shock Delivery Via Paddles or multi-function defibrillator electrode pads Reusable External Paddle Yes Pediatric Paddle Yes Multifunction Defi Pads (Disposable) Yes Energy sequence Yes Manual mode, J 1~10, 15, 20, 30, 50, 70, 100, 120, 150, 170, 200 J Synchronous Cardioversion Yes AED mode, J Fixed energy at 200 Joules Text and Voice Prompts Yes Protocol configured Yes ECG MONITOR ECG acquisition Disposable electrodes Monitors with ECG YES Input Lead I, II, III (3 Lead ECG cable) Lead I, II, III, aVR, aVL, aVF or V (5 Lead ECG cable) Lead I, II, III, aVR, aVL, aVF or V1, V2, V3, V4, V5, V6 (10 Lead ECG cable) (Display View : All 12 Lead ECG waves display simultaneously) Electrodes Yes ECG display Yes Message display Yes Heart rate display 30 to 300 bpm (±3bpm) ECG size 5, 10, 20mm/mV and Auto-gain Heart Rate/Arrhythmia Alarm HR, Asystole, VF, VT Lead Fault message Yes NONINVASIVE PACING Waveform Monophasic Truncated Exponential Mode Demand and Fixed mode Amplitude Accuracy 0 ~ 200mA (±5mA) Pulse Width 20ms (±1.5%) Pulse Rate 30 ~ 180ppm (±1.5%) Refractory Period 340 msec (30 to 80ppm) / 240 msec (90 to 180 ppm) SpO2 Pulse Oximetry SpO2 monitoring Yes (Nellcor) Saturation 70~100% (±3digits) Pulse Rate 20~250bpm (±3bpm) Perfusion 0.2% SpO2 alarm YES (Less than minimum setting rate, Over than maximum setting rate) NIBP Patient Population Adult, Pediatric, Neonate Method Oscillometric Control Autometic and manual measurements Auto Intervals 1, 3, 5, 10, 15, 30, 60, 120 min Displayed Pressures Systolic, Diastolic, Mean mmHg Displayer Units Adult : 40 to 260 mmHg Pediatric : 40 to 160 mmHg Neonate : 40 to 130 mmHg Systolic Range Adult : 20 to 200 mmHg Pediatric : 20 to 120 mmHg Neonate : 20 to 100 mmHg Diastolic Range ±3mmHg Pressure Trransducer Accuracy Adult : 300 mmHg / Pediatric 300 mmHg / Neonate : 150 mmHg Redundant Circuit Overpressure Limit PRINTER Continuous ECG Strip Real-Time (8 seconds delay) Auto Printing Recorder can be configured to print marked event, charge, shock and alarms Printing Speed 25mm/s Paper 50mm Width / 40mm Diameters DATA STORAGE Information stored ECG data, Event, Voice Internal memory Yes Even & ECG record Yes Database storage Yes External memory card Yes(SD card) EXTERNAL LINK Data management Yes Software Yes(CU-Expert) POWER SOURCE Type Lithium Polymer (14.8V 3.1Ah – Rechargeable) Integral/removable Removable Charging method AC adapter / Car Cigar Lighter Jack / both AC Power Pack Output : 18V, 6A PHYSICAL Size 318 X 208 X 355 (W X L X H, mm) Weight 5kg (with external paddle) DISPLAY Type TFT Color Size 7 inch Diagonal (152mm X 91mm) Resolution 800 X 480 pixels AUTOMATIC SELF-TEST Power on Self-Test YES Run Time Self-Test YES Manual Self-Test YES Periodic Self-Test Daily / Weekly / Monthly

Related Products